Home > Products > High Voltage Indoor Fuse > Korlen Surge Protection Device SPD AC 275V Surge Protector 2p 10ka-40ka
The Latest Product Alerts Send Me
Korlen Surge Protection Device SPD AC 275V Surge Protector 2p 10ka-40ka
  • Korlen Surge Protection Device SPD AC 275V Surge Protector 2p 10ka-40ka
  • Korlen Surge Protection Device SPD AC 275V Surge Protector 2p 10ka-40ka
  • Korlen Surge Protection Device SPD AC 275V Surge Protector 2p 10ka-40ka
Payment Type: L/C,T/T,D/P
Terms of Trade: FOB,CFR
Min. Order: 10 Bag/Bags
Delivery Time: 20 Days
Packaging: carton
Productivity: 2000000pcs/month
Brand: KORLEN / YOUTS
Transportation: Ocean
Place of Origin: WENZHOU ZHEJAING CHINA
Supply Ability: 2000000pcs/month
Certificate: ISO9001/ISO14001
HS Code: 8536200000
Port: Ningbo,SHANGHAI
Basic Info

Model No.: KNS

Product Description

Product Description


SPD Surge Protective Device,Lightning Surge Protector
Surge Protection Device (SPD)


It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.

Surge protective Device Model Selection

With the impact of international information flow, the rapid development of microelectronic science and technology, communication, computer and automatic control technology, make the building start to go for high quality, high functional area, formed a new building style-intelligent building. As inside the intelligent building there are lot of information system, <> GB50057-94(2002 vision)(hereafter brief as <>) put forward the relative requirement to install the surge protective device, to ensure the information system safely and stable running.
SPD essentially is a equipotential connection material, its model selection is according to the different lightning protection area, different lightning electromagnetic pulse critical and different equipotential connection position, decide which kind of SPD used in the area, to achieve the equipotential connection with the common earth electrode. Our statement will based on SPD's maximum discharge current Imax, continuous operating voltage Uc, protection voltage Up, alarm mode etc.
As per << Lightning Protection Norm>> item 6.4.4 stipulation "SPD must can withstand the expected lightning current flow and should confirm to the additional two requirements: the maximum clamp voltage during surge across, capable to extinguish the power frequency follow-on current after lightning current across." That is the value of SPD's max. clamp voltage add its induction voltage of two ends should be same with the system's basic insulation level and the equipment allowed max. surge voltage.

SPD for Power Supply System Series Selection Guide

The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose.
SPD for power supply system specification selection principle
Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage.
TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)
TN System: Uc≥1.15Uo
IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)
Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
SP1 Series

Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
Normal range: -5ºC~+40ºC
Extend range: -40ºC~+80ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust)

Classification

-As per Nominal Discharge Current:
5,10,20,30,40,60KA(8/20µs)
- As per Maximum continuous operating voltage:
275V,320V,385V,420V,440V,460V
- As per to poles
1P,1P+N,2P,3P,3P+N,4P
- As per auxiliary functions:
a. With remote signal output ( remote alarm function)
b. Without remote signal output

Selection Principle

- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;
- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;
- As per to the different earthing system and protection mode to select the specification accordingly;

Product Features

1, built-in over-current overheating, temperature control circuit technology.

2, the module design, easy installation, online replacement.

3, low leakage current, fast response time, low residual voltage.

4, alarm indication device, green (normal) v red (fault).

Model/Technical Parameters WR-B60 WR-B80 WR-B100 WR-B120 WR-B150
Rated Operating Voltage Un (V ~) 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V
Maximum Continuous Operating Voltage Uc (V ~) kV 385V 420V 385V 420V 385V 420V 385V 420V 385V 420V
Voltage Protection Level Up (V ~) kV ≤1.8≤2.2 ≤2.4≤2.5 ≤2.5≤3.2 ≤3.4≤3.7 ≤4.0≤4.5

Maximum Discharge

Current Imax(8/μ20μs)kA

60 80 100 120 150

Nominal Discharge

Current In(8/μ20μs)kA

30 40 60 80 100
Response Time <25 <100
L/N(mm²)The Cross Section Of L/N Line 16,25 16,25 16,25 16,25 25,35
PE (mm²)The Cross Section Of PE Line 16,25 25,35 25,35 25,35 35
Fuse or Switch (A) 63A 63A 63A,100A 63A,100A 63A,125A
The Line Section of Communication and Alarm (mm²) ≥ 1.5

Operating

Environment-C

(-40ºC~-+85ºC)
Relative humidity 25 ºC ≤95%
installation Standard Rail35mm
Material of Outer Covering Fiber Glass Reinforced Plastic
page_000004


Wenzhou Korlen Electric Appliances Co., Ltd.

 
Wenzhou korlen electric appliances co., ltd. is a joint venture. My company is a manufacturer including design, development, produce and sale, professional producing MCB, MCCB,RCCB,RCBO and AC contactor etc. product enterprise. The company owns import and export power of self-run, expanding Europe and South America, Middle East, Southeast Asia etc. market, set a good public praise.
The company have more than 1500 workers, including senior engineer among them, engineer at inside of more than 100 technician. And then set up to cover area more than 50 acres, construct area is more than 38000 square meters of the modern industrial zone, providing with the forerunner's standard laboratory and various examination equipments. Under korlen people to make great effort unremittingly, designed and developed by oneself, develop and produce the series of mcb, rccb filled up local blank, attain inter-national advanced level, and acquire more than 20 national patents.
The company acquires "30 strong eminent enterprises, top ten of export income, yueqing star class enterprise, attach importance to contract and keeps promise" title of honor for many times past years. Company still the initiative pass ISO 9001 management system verification and 14001 environments management system verification.
Our product passed quality verification of domestic and international authority organization like the CB. SEMKO. NF. SIRIM. SNI. CE .PCT. TSE, In the meantime high breaking capacity breaker of our company in this city is the unique product which got [ yueqing famous brand product" by yueqing people government. Korlen electric appliances is willing to make friends with social public, the world outside businessman join hands together for prosperous society and development to build a brighter future.

Company Info
  • Company Name: Wenzhou Korlen Electric Appliances Co., Ltd.
  • Representative: Lianggui Liu
  • Product/Service: AC Contactor , Thermal Relay , LED Light , Miniature Circuit Breaker , Residual Current Circuit Breaker , Molded Case Circuit Breaker
  • Capital (Million US $): 2800,000RMB
  • Year Established: 1985
  • Total Annual Sales Volume (Million US $): US$10 Million - US$50 Million
  • Export Percentage: 91% - 100%
  • Total Annual Purchase Volume (Million US $): US$10 Million - US$50 Million
  • No. of Production Lines: 10
  • No. of R&D Staff: 21 -30 People
  • No. of QC Staff: 31 -40 People
  • OEM Services Provided: yes
  • Factory Size (Sq.meters): Above 100,000 square meters
  • Factory Location: No.258 Wei 20 Road,Yueqing Economic&Development Zone,Zhejiang,China.
  • Contact Person: Mr. LiangguiLiu
  • Tel: 86-577-62207777